Turnstile Types: Swing, Flap, Tripod and Full-Height
Four common pedestrian gate types, what each one actually stops, and how to choose between them by throughput and security level.
Choose the turnstile by what it must physically stop. A tripod stops casual tailgating. A flap barrier stops a determined walk-through. A full-height turnstile stops climbing and crawling. A swing gate gives the highest throughput where space allows.
The four types
| Type | Throughput | Stops | Typical use |
|---|---|---|---|
| Tripod | ~25-30 per minute | Casual tailgating | Factory floors, staff entrances, gyms |
| Flap barrier | ~30-40 per minute | Walking through behind a user | Office lobbies, metro gates, building entrances |
| Swing gate | ~40-50 per minute | Tailgating, with wider passage | Airports, stadiums, accessible routes |
| Full-height | ~15-20 per minute | Climbing, crawling, passing objects over | Perimeter gates, secure compounds, cash handling areas |
Tripod turnstiles
The cheapest option and the most common. Three rotating arms allow one person per 120 degrees. They are robust and simple, but they do not stop a person who ducks under or steps over, and they are difficult to use with luggage or wheelchairs. Best for staff-only entrances where the threat model is casual.
Flap barriers
Two retracting panels form a glass or acrylic barrier. They look appropriate in a lobby and stop someone walking through behind an authorised user. The panel height and the gap above it determine what can be passed over. For higher security, specify a taller cabinet.
Swing gates
A swing gate opens a full-height panel, giving a wide clear passage. This makes it the only type suitable for wheelchair users, luggage trolleys and service access without a separate accessible lane. Throughput is the highest of the four because the passage is wide and the panels move quickly.
Full-height turnstiles
A full-height rotor inside a cabinet or cage. It is the only type that physically prevents climbing over or crawling under. Throughput is the lowest and the footprint is the largest. Use it where the perimeter matters more than speed: secure compounds, cash rooms, restricted floors.
What to specify alongside the gate
- Reader type — card, QR, face recognition or fingerprint, and whether it mounts on the cabinet or on a pedestal
- Direction control — one-way or bi-directional
- Emergency release — the gate must open freely when the fire alarm triggers
- Accessible route — a wide gate or a separate accessible lane is required by most building codes
Frequently asked
Can a turnstile count people?
Yes. Most controllers log each passage and report counts per lane, which is often more useful than the access control function itself.
What happens during a power failure?
Fail-safe configuration drops the barriers so people can leave. Fail-secure keeps them closed. Fire codes generally require fail-safe on escape routes.